6.0 Hydraulic & Pneumatic Control
Fuellox for Service trucks will control a pump via a solenoid.
6.1 Pneumatic Control
Fuellox can switch a simple solenoid to energise pneumatic pumps.
Parts
Label | Part | Description |
---|---|---|
U | Air Source | |
V | Fuellox Relay | |
W | 2 port normally closed | Energise to open, spring return |
Y | Air Powered Pump | Diaphragm Pump |
X | External Bypass | 2 Position Lockable* Ball Valve |
*Note: Use a lockable ball valve to prevent unauthorised usage
6.2 PTO Control
The PTO Control design facilitates the use of a hydraulic rewind hose reel. In these cases, Fuellox needs to start/stop the pump without affecting the operation of the hose reel.
Parts
Label | Part | Description |
---|---|---|
A | Existing Pump Hydraulics | Without Fuellox |
B | New Pump Hydraulics | After Fuellox |
C | Flow meter or Register Pulser | LCR, Veeder Root, Hall Effect |
D | Fuellox HD | Mobile Variant for solenoid control |
1 | Hydraulic Source to Pump | |
2 | Solenoid | 3 Port 2 Position, power to open spring return |
3 | Pump | PTO Drive Pump Motor |
4 | Ball Valve | 3 way lockable* ball valve, external bypass |
*Notes:
- Use a lockable ball valve to prevent unauthorised usage
- Depending on conguration and port arrangement an “L” or “T” type 3 way valve may be needed
Hydraulics
In some cases fuel truck hydraulics can be associated with safety critical systems. Be sure to engage a specialist for Hydraulic system modifications
6.3 PTO Control Concepts
6.3.1 Not Authorised
6.3.2 Fuellox Authorised
6.3.3 External Bypass
6.3.4 Control Summary
Label | Not Authorised | Authorised | Bypass |
---|---|---|---|
1 | Pressure | Pressure | Pressure |
2 | Closed | Open | Closed |
3 | Off | On | On |
4 | Closed | Closed | Open |